Technical Data 



Collector Model
HC-50
HC-40
HC-30
HC-12.5
HC-10
Size, Nominal
4'x12.5'
4'x10.5'
4'x8'
1'x12.5'
1'x10.5'
Width
47" / 120cm
47" / 120cm
47" / 120cm
11.75"
11.75"
Length
152.1" / 380cm
127" / 323cm
91" / 231cm
151.5"
127"
Area (sq. ft.)
50.0 / 4.65m^3
41.6 / 3.88m^3
30.0 / 2.77m^3
12.2
10.2
Manifold Diameter
2" / 5.08cm
2" / 5.08cm
2" / 5.08cm
2"
2"
Weight, Dry
22lbs / 10kg
19lbs / 8.5kg
15lbs / 6.8kg
5.5lbs
4.75lbs
Volume Capacity
3.7gal / 14L
3.1gal / 12L
2.4gal / 9L
.93gal
.78gal
Working Pressure
90 PSI
90 PSI
90 PSI
90 PSI
90 PSI
Burst Pressure
270 PSI
270 PSI
270 PSI
270 PSI
270 PSI
Recommended Flow
5 GPM
4 GPM
4 GPM
1.25 GPM
1 GPM
BTU Per Day
Collector Size
Int' Standard
ORTECH
National
SRCC
Florida Standard
FSEC Data
HC-50
4'x12.5'
47,400
47,400
45,000
HC-40
4'x10.5'
39,400
39,400
37,440
HC-30
4'x8'
28,440
28,440
27,000
Performance
Equations
.872 - 3.729 (Ti - TA) / I
K
AX = 1.00 - .0316(S) - .0104(S)2
.825 - 3.74 (Ti-TA)/I
K
AX=1.00-0.4(S)

Performance Note:
Solar Scientists agree that there are many variables to consider when properly sizing a system. Wind conditions, micro climates, flow rates, orientation and shading of the pool and/or collectors all effect the performance of your system. A BTU rating is just one of the many factors to consider.


Collector Rating Numbers
Thousands of BTU's per Day per Panel

Category ^T (oF)

2,000 BTU/ft2
Solar Insolation
1,500 BTU/ft2

1,000 BTU/ft2
Water
Temp.

minus

Air
Temp.

A (-9)
98.74
78.07
57.49
B (+9)
64.13
44.01
23.96
C (+36)
22.91
7.64
0
D (+90)
0
0
0
E (+144)
0
0
0

Copyright 2005 Green Energy Inc. USA All Rights Reserved.